Ingredior STEEL

Why Choose Us

All what You Need To Know About Us

Ingredior STEEL Co., Ltd. is a company specialized in mild steel plate,shipbuilding steel plate,Boiler steel,Weathering steel plateThe supply capacity per year is about 8,900,000 tons steel plate/coil according to EN10025,EN10028,ASTM A36,ASTM A131, JIS G3101,JIS G3106...

  • Gas cylinder steel plate

    Gas cylinder steel plate

    Gas cylinder steel plate is used in welded gas cylinder and related products. supplies gas cylinder steel with better anti-stress capability. Popular......

    More
  • Shipbuilding steel plate

    Shipbuilding steel plate

    shipbuilding steel plate suppliers,we supply A,B,D,E,AH32,DH32,EH32,FH32,AH36,DH36,EH36,FH36,AH40,DH40,EH40,FH40 with ABS,DNV,GL ....

    More
  • Boiler pressure vessel steel

    Boiler pressure vessel steel

    Boiler and pressure vessel grade steel comes in a variety of grades and thicknesses, and are designed to withstand the immense internal ......

    More
  • Alloy steel Plate

    Alloy steel Plate...

    Alloy steel is steel that is alloyed with a variety of elements in total amounts between 1.0% and 50% by weight to improve its mechanical properties. ...

    More
  • Q345B steel plate

    Q345B steel plate

    Steel grade Q345B is the most common used as high strength low alloy structural steel in industry area. ...

    More
  • Q235B steel plate

    Q235B steel plate

    Q235 steel is Chinese structural steel, Q235A Q235B Q235C Q235D material density: 7.85 g/cm3, properties, specification, composition .. ..

    More

Quick Message

Fill in this form or click the service online, all questions will be answered.

EN 1522 FB4 anti explosion steel

  • Architectural Armour Bullet Resistant Windows UK

    Ballistic Technical Specifications. EN1063 Glass in Building Security Glazing Testing and Classification of Resistance Against Bullet Attack. UL752 Standard for Bullet Resisting Equipment. BS5051 Bullet resistant glazing Part 1for interior use Part 2for Exterior use. NIJ 0108.01 US National Institute of Justice Standard Test and Certification for Ballistic Resistant MaterialsRead More

  • Norms & Standards SÄLZER GmbH

    must be equipped with anti panic locks according to EN 179 or EN 1125. In case of emergency the door must be operable quickly by using the panic bar or the door handle. By using the panic function all locks are pulled back at once. This type of mechanism increases the risk of burglary considerably, espe Read More

  • Bullet Proof Steel Doors Ballistic Rated Steel Security

    Tested in accordance with EN 1522 1 class FB4 NS standard, area 1. Weld resistance tested to CE EN 1435 1 1. Additionally tested using the following missilesNP (new police bullet) // A3 action 3 // Action effect // Ball syntox (DM41).Read More

  • Ballistic Standards for Armored Vehicles Aurum Security

    Abbreviation "FB" is defined in the standard DIN EN 1522 and is used to indicate the protection level of opaque (non transparent) materials, such as armor steel, kevlar, twaron, aramid, UHMwPE (Ultra High Molecular weight Polyethylene like Dyneema or Spectra), ceramic etc.Read More

  • Collbaix Security Shutters Products

    DIAMOND BL has been specifically designed to provide high ballistic protection in your buildings according to the European Standard EN 1522 and certified CLASS 3 of resistance of wind load according to UNE EN 12424. Using slats of 50 mm height, this model can be installed in tight spaces offering bulletproof FB4 S certified protection.Read More

  • DEsignED sEcuRiTY hammerglass

    BR6 NS (EN 1063) Reinforced stainless steel partitions, Security Class FB4/ FB6 (EN 1522) Thinner and lighter than comparable glass solutions We can provide you a comprehensive turnkey solution including risk analysis and security needs assessment. BALLisTic & EXPLOsiOn PROTEcTiOnRead More

  • DEsignED sEcuRiTY hammerglass

    BR6 NS (EN 1063) Reinforced stainless steel partitions, Security Class FB4/ FB6 (EN 1522) Thinner and lighter than comparable glass solutions We can provide you a comprehensive turnkey solution including risk analysis and security needs assessment. BALLisTic & EXPLOsiOn PROTEcTiOnRead More

  • Strongdor Technical specifications

    The ballistic resistance has been tested in accordance with the EN 1522 1 class FB4 NS standard, area 1. Weld resistance tested to CE EN 1435 1 1. In addition to this class, the doors are tested using the following missilesNP (new police bullet) A3 action 3 Action effect Ball syntox (DM41)Read More

  • (PDF) Ductal ® An Ultra High Performance Material for

    Ductal ® An Ultra High Performance Material for Resistance to Blasts and Impacts defined in NF EN 1522 (FB4+, FB5, FB6, and FB7). 75mm and 100mm were tested against an explosion of 5 Read More

  • AB® High performance bullet resistant protection!

    Glazing must always be fitted into frames of an equivalent class. The bullet resistance of window frames is indicated by their classification as FB or FSG (EN 1522 & EN 1523). For exampleClass BR4 bulletproof glazing must be fitted in a FB4 frame; SG1 or SG2 glazing must by fitted into an FSG classification frame.Read More

  • Laminated high performance anti bullet AB RIOU Glass

    The glazing must always be integrated into equivalent class chassis. The resistance of joinery to the balls is given by their class FB or FSG (EN 1522 & EN 1523). ExampleA BR4 class bullet proof glazing must necessarily be integrated into an FB4 chassis, SG1 or SG2 glazing must also be installed in an FSG rated chassis. 4 sided rebate required.Read More

  • UNBREAKABLE. Hammerglass

    Mounting in Hammerglass stainless steel bullet proof reinforced partitions (Security Classes FB4 and FB6, EN 1522) provides complete protection against ballistic attacks. The ballistic resistance relates to both the glass and the accompanying frame. We can provide you complete solutions with customized ballistic steel systems for windowRead More

  • Interlocks and Automation GUNNEBO ENTRANCE

    Security Airlocks Cristal II Cristal II is the only square shaped security airlock on the market with fully certified ballistic and burglary resistance. The airlock has been independently tested to meet the EN 1522 standard for bullet resistance to level FB4 and the ENV 1627 standard for burglary resistance to Level 4.Read More

  • SECUFIRE saelzer security

    SECUFIRE® was tested according to the European standard for bullet resistance DIN EN 1522 + 1523 in the re sistance class FB4 NS. In this class, the test specimen is shot several times from a 5 m distance with a handgun, caliber 357 Magnum und 44 Rem. Magnum. The addition NS means no splinters, no splinters flew out of theRead More

  • Resistance of slim UHPFRC targets to projectile impact

    This paper presents the results from ballistic testing of three Ductal® classes (140MPa, 170MPa, and 210MPa) against four impact classes defined in NF EN 1522 (FB4+, FB5, FB6, and FB7).Read More

  • Land Applications industry.defence industries

    armoured with steel For a small cabin armoured to defeat 7.62 x 51 AP the difference in weight can easily be 500 kg. Technical SpecificationsBallistic level Level 1 to 4 according to NATO STANAG 4569 or EN 1522 level FB6 or FB7 Materials Aramid and Ceramic Polyethylene and Steel Weight From 34 Read More

  • Interlocks and Automation GUNNEBO PDF Catalogs

    Security Airlocks Cristal II Cristal II is the only square shaped security airlock on the market with fully certified ballistic and burglary resistance. The airlock has been independently tested to meet the EN 1522 standard for bullet resistance to level FB4 and the ENV 1627 standard for burglary resistance to Level 4.Read More

  • Collbaix Security Shutters Regulations Marine Armor System

    Therefore, we use technological and extremely resistant materials in the manufacture of our products, based on high strength hardened aluminum alloys, which are very light and at the same time more resistant than steel.. Kriptonia series safety systems have been tested and certified under the most stringent European standards in ballistic resistance, anti theft, wind loading, fire resistance Read More

  • Schedule of Accreditation issued by

    FB4 FB5 FB6 FB7 FSG Ammounition (Other Type & Calibres) BS EN 1522 1999 Windows, doors, shutters and blinds Requirements and classification. BS EN 1523 :1999 Windows, doors, shutters and blinds Bullet resistance Test method. KADDB Ballistic testing facility Indoor Range Protective Materials (Metals, Ceramics,Read More

  • Produkte Buchele

    Produkte (33) Wednesday, 11 January 2017 19:10 BUCHELE doors on one hand reduce the risk of an explosion on the other hand the doors withstand a pressure load in an emergency situation. Depending on the amount and type of stored substances each pressure proof door is uniquely designed, calculated and manufactured according to customers Read More

Quick Message

Fill in this form or click the service online, all questions will be answered.

Quick Message

Fill in this form or click the service online, all questions will be answered.